Base Operating System and Extensions Technical Reference, Volume 1
pmlib_get_event_notice Subroutine
Purpose
Gets a new PM event.
Library
PM (Power Management) Library (libpm.a)
Syntax
#include <pmlib.h>
int pmlib_get_event_notice(event)
int *event;
Description
The pmlib_get_event_notice subroutine gets the latest event. It is recommended PM- aware application calls this subroutine when signal notification from pm daemon arrives.
Parameters
event |
Points to an integer that is the latest PM event that the PM daemon holds, event can be bit-wise OR of following values:
- PMLIB_EVENT_NONE
- No event.
- PMLIB_EVENT_AC
- Power source is changed to AC.
- PMLIB_EVENT_DC
- Power source is changed to DC.
- PMLIB_EVENT_NOTICE_TO_FULL_ON
- System will change state to full-on.
- PMLIB_EVENT_NOTICE_TO_STANDBY
- System will change state to standby.
- PMLIB_EVENT_NOTICE_TO_SUSPEND
- System will change state to suspend.
- PMLIB_EVENT_NOTICE_TO_ENABLE
- System will change state to PM enable.
- PMLIB_EVENT_NOTICE_TO_HIBERNATION
- System will change state to hibernation.
- PMLIB_EVENT_NOTICE_TO_SHUTDOWN
- System will change state to shutdown.
- PMLIB_EVENT_NOTICE_TO_TERMINATE
- PM will be unconfigured.
- PMLIB_EVENT_NOTICE_OF_REJECTION
- State change request was rejected.
- PMLIB_EVENT_NOTICE_COMPLETION
- State change was completed.
- PMLIB_EVENT_RESUME_FROM_STANDBY
- System is resumed from standby.
- PMLIB_EVENT_RESUME_FROM_SUSPEND
- System is resumed from suspend.
- PMLIB_EVENT_RESUME_FROM_HIBERNATION
- System is resumed from hibernation.
- PMLIB_EVENT_START_TO_CHANGE_STATE
- System state change started.
- PMLIB_EVENT_FORCE_TO_CHANGE_STATE
- System is forced to change state.
- PMLIB_EVENT_FAIL_TO_CHANGE_STATE
- System state change failed.
|
Return Values
Upon successful completion, PMLIB_SUCCESS is returned. If the pmlib_get_event_notice subroutine fails, PMLIB_ERROR is returned and errno variable is set to an error code.
Error Codes
ESRCH |
PM daemon is not running. |
EINVAL |
Invalid argument. |
Note: If an application program is registered as PM aware, the PM daemon sends a SIGPM (equal to SIGPWR) signal to the application when an PM event occurs. The application program needs to prepare a signal handler and to use this pmlib_get_event_notice subroutine to get the to get the PM event.
Implementation Specifics
The pmlib_get_event_notice subroutine is part of the Base Operation System (BOS) Runtime.
Related Information
The pmlib_request_state subroutine, pmlib_request_battery subroutine, pmlib_request_parameter subroutine, pmlib_register_application subroutine.